Barcode Printing (cont.)
Mnemonic Function Command Remarks
Parameter Description Value
P
n3
Width of quiet
zones in
decipoints
Supported value: 180.
P
n4
Width of wide
bars in decipoints
For EAN, UPC, supported values are in
the range 20 to 158 (default is 25).
P
n4
is not used for Code 93, MSI 10/10 and
Code 128 systems.
Postnet bar code style is fixed to 0,0217" for
bars and to 0,0255" for spaces. Pitch is 21,18
bars/inch.
P
n5
Ignored
P
n6
Height of bars in
decipoints
Min = 60
Max = 2400
Default = 120
P
n7
Ignored
P
n8
Orientation 0, 1 or none : Horizontal symbol from left
to right (portrait)
3: Vertical symbol from bottom to top
(landscape - not applicable for EAN 8 & 13,
UPC A & E
P
s9
Human Readable
Characters
0, 1: No HRC
2, 3, 4: Print HRC in OCR B
Ignored for Postnet