Compuprint 4247 Serial Guia do Utilizador Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 204
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
Performing a power-receptacle safety-check
DANGER
<1-10> Hazardous voltages are present. Do not touch the pins or sockets of
the power receptacle.
For pluggable equipment, the socket-outlet shall be installed near the equipment
and shall be easily accessible.
“Portable power strip receptacles (temporary power taps)” on page xii, conforming
to all requirements, may be used.
A qualified electrician should perform all checks necessary to ensure safe
operation. These should include the following checks and any other required by
local regulations.
v Check the AC voltage at all associated power receptacles (see “4247 Model Z03
Printer nominal AC input power requirements”).
v Check that all associated power receptacles are properly grounded.
4247 Model Z03 Printer nominal AC input power requirements
Attention: If the voltages are not within the correct operating range, allow for
correction before the equipment is plugged in and operated.
Nominal Voltage Voltage Range Amps Phase / Hz
100–230 Vac 90–264 Vac 2.9–1.3 A Single phase /
50–60 Hz
Chapter 1. Getting Started 3